Systematic ventilation

logo3

THE SPECIALIST FOR STATE-OF-THE-ART CONCEPTS

Made in Europe
foto1

Natural
ventilation

badge
foto2

Semi-mechanical & mechanical ventilation

foto3

Weather protection grilles, louvre walls & pressure relief flaps

What defines us

Industrial aeration & ventilation systems

Systematic
Ventilation

From one source

PLANNING, PRODUCTION AND INSTALLATION

Consulting, sales, design and production in-house, installation and maintenance of new and existing systems on-site. Our professionalism and flexibility are reflected in the wide spectrum of our customers: from international industrial groups that work under the highest heat loads to medium-sized production companies.

Our services at a glance

LOUVERS FOR NATURAL VENTILATION

The Weather Protection Louver ensures an energy free supply of fresh air to a building. The aerodynamically designed blades offer a high efficiency as they were optimized with regard to fluidic characteristics according to DIN EN 12101 on the test stand. They are horizontally fixed in the frame. Optionally they are available as sound insulation in double-walled construction.

FACADE CLADDING

The Weather Protection Louver Wall is a further development of the LU-F. For the LU-FW the blades are horizontally fixed onto a girder system, thus providing a continuous band and offering a high quality appearance of the cladding with identical properties and performances as described for the LU-F.

NATURAL SMOKE EXTRACTION (SHE)

The complex systems are available for all common applications. From puristic roof hatch to architectural fire ventilation wing, the systems are always performance-optimised and highly functional. Depending on requirements, they provide daylight, are weather-independent, permanently dissipate production heat and are optimised for high throughput as well as for daily ventilation.

MAINTENANCE

Roof ventilators, flat ventilators or mechanical ventilation — we have the perfect solution even for particularly challenging circumstances and space conditions. Depending on the design, our exhaust air systems are flexible in shaft width and can also be used for ventilation and smoke extraction compliant with EN 12101-2; additional devices for smoke extraction are therefore no longer necessary. Moreover, the exhaust systems prevent rain and snow from penetrating even with a full ventilation cross-section, are space-optimised and as a result can be used where conventional ventilation systems are at their limits and neither natural ventilation nor mechanical air supply via ductwork is possible.

MECHANICAL VENTILATION

To supplement our portfolio of natural ventilation and smoke extraction, we offer mechanical ventilation systems for special industrial applications, including applications in the automotive and pharmaceutical industries.

TECHNICAL ENGINEERING

Collect facts, clarify special requirements in dialogue with you and then as a team scrutinize the project from all angles. The energy of our young colleagues’ merges with the experience of our long-standing employees: an unbeatable combination!

SOUND INSULATION

The Weather Protection Louver ensures an energy free supply of fresh air to a building. The aerodynamically designed blades offer a high efficiency as they were optimized with regard to fluidic characteristics according to DIN EN 12101 on the test stand. They are horizontally fixed in the frame. Optionally they are available as sound insulation in double-walled construction.

THERMODYNAMIC CALCULATIONS

We deliver the best results in all areas – whether thermodynamic calculations, preliminary planning, or detailed engineering. High flexibility and modern technology enable us to offer you both, large series production and special constructions. Our clients come from international industrial groups that work under the highest heat loads to medium-sized production companies.

Our clients

01.STEEL INDUSTRY min
02.WASTE TREATMENT INDUSTRY min
03.FLAT GLASS INDUSTRY min
04.CONTAINER GLASS INDUSTRY min
05.CHEMICAL INDUSTRY min
06.ALUMINIUM INDUSTRY min
07.CEMENT INDUSTRY min
08.ENERGY PRODUCING INDUSTRY min
09.COPPER INDUSTRY min
10.ANLAGEN CONSTRUCTION min
11.FOUNDRY min
12.PRODUCTION FACILITIES min
01.STEEL INDUSTRY min
02.WASTE TREATMENT INDUSTRY min
03.FLAT GLASS INDUSTRY min
04.CONTAINER GLASS INDUSTRY min
05.CHEMICAL INDUSTRY min
06.ALUMINIUM INDUSTRY min
07.CEMENT INDUSTRY min
08.ENERGY PRODUCING INDUSTRY min
09.COPPER INDUSTRY min
10.ANLAGEN CONSTRUCTION min
11.FOUNDRY min
12.PRODUCTION FACILITIES min

Contact us!

We are looking forward to hearing from you
please do not hesitate to contact us
natürliche Belüftung Prozess 1

Bezeichnet den Luftaustausch in Bauwerken durch natürliche Druckunterschiede (Kamineffekt) zwischen Innenraum und Außenluft.

Bei industriell genutzten Gebäuden ist meist ein thermischer Hotspot der Motor dieser Lüftung.

Vorteile: keine zusätzliche Energie wird für diese Lüftung benötigt (CO2 neutral).

Refers to the exchange of air in buildings through natural pressure differences (chimney effect) between the interior and exterior air.

In industrially used buildings, a thermal hotspot is usually the motor of this ventilation.

Advantages: no additional energy is required for this ventilation (CO2 neutral).

Ist der Luftaustausch wegen zu geringer Wärmelast nicht möglich, werden Ventilatoren im Zuluft Element oder im Abluft Element eingesetzt.

Reicht diese Maßnahme auch nicht aus kann durch eine mechanische Lüftung der Luftaustausch des Industrie Gebäudes verwirklicht werden (keine Komfort Lüftung).

If the air exchange is not possible due to insufficient heat load, fans are used in the supply air element or in the exhaust air element. If this measure is also insufficient, the air exchange of the industrial building can be realized by mechanical ventilation (no comfort ventilation).

Wetterschutzgitter und Lamellenwände sind auch als Design Element für Ihr Gebäude perfekt geeignet. Sie sind aerodynamisch optimiert und zertifiziert. Auch könne Sie zur Schalldämmung eingesetzt werden. 

Druckentlastungsklappen schützen Ihr Gebäude und sind ein unverzichtbares Element in der Schwerindustrie.

Weather protection grilles and louvered walls are also perfectly suited as design elements for your building. They are aerodynamically optimized and certified. They can also be used for sound insulation. 

Pressure relief dampers protect your building and are an indispensable element in heavy industry.

Schaltanlagengebäude/ Trafoanlagen

Auch mechanische Lüftungskomponenten oder Hybridlösungen werden von Aerotec Europa verwirklicht. Hier besteht eine Vertriebskooperation mit der Firma Heber und anderen namhaften Unternehmen. Wir bieten für jede lüftungstechnische Anforderung in der Industrie die ideale Lösung. Sonderanfertigung werden nach Kundenwunsch verwirklicht und garantieren eine maßgeschneiderte Be- und Entlüftung ihrer Halle

Also mechanical ventilation components or hybrid solutions are realized by Aerotec Europe. In this field, there is a sales cooperation with the company Heber and other well-known companies. We offer the ideal solution for every ventilation requirement in the industry. Special designs are realized according to customer requirements and guarantee a customized ventilation of your hall.

Flughafen/Parkhäuser

Lamellenwände sind nicht nur als regensicher und schalldämmende Maßnahme zu sehen, sondern sind auch eine optische Aufwertung eines Gebäudes. Durch Jahrzehnte langer Erfahrung und Entwicklung sind unsere Wetterschutz Lamellenwand LU-FW eine optimale Lösung. Auch bieten wir Entrauchungsgeräte und Lichtbänder im Dach an. 

Lamella walls are not only to be seen as a rainproof and sound-absorbing measure, but are also an optical enhancement of a building. Due to decades of experience and development, our weather protection lamella wall LU-FW are an optimal solution. We also offer smoke extraction units and light bands in the roof.

Kalorische Energieerzeuger

Die durch den Verbrennungs Prozess entstehende Abwärme wird mittels Windleitflächenlüfter am Dach abgeführt. Hier haben sich unsere Produkte, wie der RVI-II oder der RVI-II Akustik als Multitalent bewährt. Die nachströmende Luft wird durch Wetterschutz Jalousien LU-O, LU-O-A oder Außenluftsysteme mit Schalldämmkulissen und Wärmetauscher LU-K eingeleitet. Auch kommen Wetterschutzgitter LU-F oder Wetterschutz Lamellenwände LU-FW zum Einsatz.

The waste heat generated by the combustion process is dissipated by means of wind guide surface fans on the roof. Here, our products, such as the RVI-II or the RVI-II Acoustics have proven to be multi-talented. The incoming air is introduced through weather protection blinds LU-O, LU-O-A or outdoor air systems with sound absorbing baffles and heat exchangers LU-K. Weather protection grilles LU-F or weather protection lamella walls LU-FW are also used.

Thermische Müllverwertungsanlage

Bei einer Müllverwertungsanlage wird die, durch den Verbrennungs Prozess entstehende Abwärme, mittels Windleitflächenlüfter am Dach abgeführt. Hier haben sich unsere Produkte, wie der RVI-II oder der RVI-II Akustik als Multitalent bewährt. Die nachströmende Luft wird durch Wetterschutz Jalousien LU-O, LU-O-A oder Außenluftsysteme mit Schalldämmkulissen und Wärmetauscher LU-K eingeleitet.

In a waste incineration plant, the waste heat generated by the incineration process is dissipated by means of wind deflector fans on the roof. Here, our products, such as the RVI-II or the RVI-II Acoustics have proven to be multi-talented. The incoming air is introduced through weather protection blinds LU-O, LU-O-A or outdoor air systems with sound absorbing baffles and heat exchanger LU-K.

Eisenmetall- Nichteisenmetall Erzeuger

Thermische Prozesse, wie zum Beispiel in einem Hochofen, beim LD Verfahren oder in einer Elektrolyse, benötigen eine ideale Be- und Entlüftung. Für die Fortluft wird meist unser Windleitflächenlüfter RVI-II eingesetzt (auch als RWA und Akustikausführung RVI-II-A). Die nachströmende Luft wird durch Wetterschutz Jalousien LU-O, LU-O-A oder Außenluftsysteme mit Schalldämmkulissen und Wärmetauscher LU-K eingeleitet.

Thermal processes, such as those in a blast furnace, LD process or electrolysis, require ideal ventilation and venting. For the exhaust air, our wind guide surface ventilator RVI-II is usually used (also as SHEVS and acoustic version RVI-II-A). The incoming air is introduced through weather protection blinds LU-O, LU-O-A or outdoor air systems with sound absorbing baffles and heat exchanger LU-K.

Glashütte

Durch den anspruchsvollen thermischen Prozess, beim Gießen von Flach- Behälterglas wird die Produktionswärme durch unsere Windleitflächenlüfter RVI-II abgeleitet (auch als RWA und Akustikausführung RVI-II-A). Die nachströmende Luft wird durch Wetterschutz Jalousien LU-O, LU-O-A oder Kombigeräte mit Schalldämmkulissen LU-SD eingeleitet.

Due to the demanding thermal process during the casting of flat container glass, the production heat is dissipated by our wind vents RVI-II (also available as SHEVS and acoustic version RVI-II-A). The incoming air is introduced through weather protection blinds LU-O, LU-O-A or combination units with sound absorbing baffles LU-SD.